5 research outputs found

    Open pancreaticoduodenectomy: setting the benchmark of time to functional recovery

    Get PDF
    Purpose No accepted benchmarks for open pancreaticoduodenectomy (PD) exist. The study assessed the time to functional recovery after open PD and how this could be affected by the magnitude of midline incision (MI).Materials and methods Prospective snapshot study during 1 year. Time to functional recovery (TtFR) was assessed for the entire cohort. Further analyses were conducted after excluding patients developing a Clavien-Dindo >= 2 morbidity and after stratifying for the relative length of MI.Results The overall median TtFR was 7 days (n = 249), 6 days for uncomplicated patients (n = 124). A short MI (SMI, < 60% of xipho-pubic distance, n = 62) was compared to a long MI (LMI, n = 62) in uncomplicated patients. The choice of a SMI was not affected by technical issues and provided a significantly shorter TtFR ( 5 vs 6 days, p = 0.002) especially for pain control (4 vs. 5 days, p = 0.048) and oral food intake (5 vs. 6 days, p = 0.001).Conclusion Functional recovery after open PD with MI is achieved within 1 week from surgery in half of the patients. This should be the appropriate benchmark for comparison with minimally invasive PD. Moreover, PD with a SMI is feasible, safe, and associated with a faster recovery

    Evaluation of Five New Liquid Stable Applications on the Roche Cobas Integra

    Get PDF
    In the present study the analytical performances of five new liquid applications on the Roche Cobas Integra were evaluated: urea and high density lipoprotein (HDL) cholesterol in serum and glucose, creatinine and inorganic phosphorus in urine.Peer Reviewe

    Short-term stability of free metanephrines in plasma and whole blood

    No full text
    Background Analysis of plasma metanephrine (MN) and normetanephrine (NMN) with liquid chromatography tandem mass spectrometry (LC-MS/MS) is the gold standard for the screening of pheochromocytomas and paragangliomas (PPGLs). As scarce information is available on the stability of MNs in diagnostic samples, this study was aimed at analyzing the short-term stability of plasma free MNs in whole blood and plasma, using LC-MS/MS. Methods The stability of plasma MNs was evaluated after sample collection at 1, 2 and 3 h in whole blood, and at 2, 4 and 6 h in centrifuged samples. Both studies were performed while maintaining the samples at room temperature (RT) and at 4\u2009\ub0C. The ClinMass Complete Kit (Recipe, Munchen, Germany) was used for measuring MNs with LC-MS/MS (Nexera X2 UHPLC-4500MD Sciex). Differences from the baseline (T0) were assessed using repeated measures one-way ANOVA, Students' paired t-test and a comparison of the mean percentage changes with the total change limit (TCL). Results Statistically significant differences from T0 were found for both MNs (p\u2009<\u20090.001) in whole blood stored at RT, and for NMN (p\u2009=\u20090.028) but not MN (p\u2009=\u20090.220) at 4\u2009\ub0C. The mean difference exceeded the TCL after 1 h and 3 h at RT for MN, and after 1 h at RT for NMN. Statistically significant differences from T0 were only observed in the plasma samples for NMN at RT (p\u2009=\u20090.012), but the variation was within the TCL. Conclusions MN and NMN displayed different patterns of stability before and after centrifugation. Even short-time storage at RT in whole blood should hence be avoided

    Augmented reality (AR) in minimally invasive surgery (MIS) training: where are we now in Italy? The Italian Society of Endoscopic Surgery (SICE) ARMIS survey

    No full text
    Minimally invasive surgery (MIS) is a widespread approach in general surgery. Computer guiding software, such as the augmented reality (AR), the virtual reality (VR) and mixed reality (MR), has been proposed to help surgeons during MIS. This study aims to report these technologies' current knowledge and diffusion during surgical training in Italy. A web-based survey was developed under the aegis of the Italian Society of Endoscopic Surgery (SICE). Two hundred and seventeen medical doctors' answers were analyzed. Participants were surgeons (138, 63.6%) and residents in surgery (79, 36.4%). The mean knowledge of the role of the VR, AR and MR in surgery was 4.9 ± 2.4 (range 1-10). Most of the participants (122, 56.2%) did not have experience with any proposed technologies. However, although the lack of experience in this field, the answers about the functioning of the technologies were correct in most cases. Most of the participants answered that VR, AR and MR should be used more frequently for the teaching and training and during the clinical activity (170, 80.3%) and that such technologies would make a significant contribution, especially in training (183, 84.3%) and didactic (156, 71.9%). Finally, the main limitations to the diffusion of these technologies were the insufficient knowledge (182, 83.9%) and costs (175, 80.6%). Based on the present study, in Italy, the knowledge and dissemination of these technologies are still limited. Further studies are required to establish the usefulness of AR, VR and MR in surgical training
    corecore